Questions? 1-800-356-5221

Chat with a 5-star expert now!

Questions? 1-800-356-5221

Chat with a 5-star expert now!

  1. Home /
  2. CPAP Supplies /
  3. CPAP Humidifiers /
  4. Heated Humidifiers /
  5. Philips Respironics

60 Series Heated Humidifier for Non-Heated Tubing

BY Philips Respironics  |  Item #DS6H
(9) Read Reviews
$129.00

Prescription Required for Purchase

Need Replacement Parts or Accessories? Shop now

Get Your Sleep Back

Face Sleeping

Setup is easy & takes minutes

Truck Fast

Orders ship within hours (M-F)

Arrows Rotate

Resupply items set to autopilot

Item # DS6H

Not currently in stock

60 Series Heated Humidifier for Non-Heated Tubing
60 Series Heated Humidifier for Non-Heated Tubing
60 Series Heated Humidifier for Non-Heated Tubing
60 Series Heated Humidifier - Non-Heated Tube
Click image to expand
60 Series Heated Humidifier for Non-Heated Tubing 60 Series Heated Humidifier for Non-Heated Tubing 60 Series Heated Humidifier - Non-Heated Tube
1/3
60 Series Heated Humidifier for Non-Heated Tubing 60 Series Heated Humidifier for Non-Heated Tubing 60 Series Heated Humidifier - Non-Heated Tube
1/3

60 Series Heated Humidifier for Std Hose

Wake up refreshed with the 60 Series Heated Humidifier for Non–Heated Tubing, which is designed to provide warm, humidified air to your sinuses, nose, and throat. 

Learn More About the 60 Series Heated Humidifier for Non–Heated Tubing:

  • Reduces Condensation Build–Up to Minimize Sleep Disruptions 
  • Works With Certain Devices Like the REMStar 60 Series Machines From PR System One
  • Can Provide Relief to Irritated Sinuses

60 Series Heated Humidifier for Std Hose

Wake up refreshed with the 60 Series Heated Humidifier for Non–Heated Tubing, which is designed to provide warm, humidified air to your sinuses, nose, and throat. 

Learn More About the 60 Series Heated Humidifier for Non–Heated Tubing:

  • Reduces Condensation Build–Up to Minimize Sleep Disruptions 
  • Works With Certain Devices Like the REMStar 60 Series Machines From PR System One
  • Can Provide Relief to Irritated Sinuses

The 60 Series Heated Humidifier for Std Hose is Right for You!

Product Highlight Included Parts Placeholder

What's included*

  • 60 Series Non-Heated Tube Humidifier
  • Water Chamber for Respironics 60 Series
  • PR One Humidifier Dry Box & Inlet Seal
  • Humidifier Elbow Seal for PR System One

+ View More

* Does not include select added accessories

Learn More About This Product

Reduces Condensation Build–Up to Minimize Sleep Disruptions 

This heated humidifier helps prevent the air from cooling before it reaches the mask and minimizes built–up condensation, which can cause sleep disruptions.

Works With Certain Devices Like the REMStar 60 Series Machines From PR System One

This product is compatible with the following devices:

  • PR REMStar 60 Series Auto with Bluetooth
  • PR REMStar 60 Series Pro CPAP Machine with Bluetooth
  • PR System One REMStar 60 Series BiPAP Auto with Bluetooth
  • PR System One REMStar 60 Series Auto CPAP
  • PR System One REMStar 60 Series Pro CPAP Machine
  • PR System One REMStar 60 Series BiPAP Auto with Bi-Flex
  • PR System One REMStar 60 Series BiPAP Pro with Bi-Flex
  • PR System One REMstar 60 Series Plus CPAP Machine with C-Flex
  • PR System One REMStar 60 Series SE CPAP Machine

For use with non–heated hoses only; this product does not have a mechanism to attach heating coils.

What’s Included:

  • 60 Series Non-Heated Tube Humidifier
  • Water Chamber for Respironics 60 Series
  • PR One Humidifier Dry Box & Inlet Seal
  • Humidifier Elbow Seal for PR System One
  • Atmospheric Pressure: 77 to 101 kPa (0 - 7500 ft.)
  • Standards Compliance: This humidifier is designed to conform to the following standards: IEC 60601-1 General Requirements for Safety of Medical Electrical Equipment EN ISO 8185 General Requirements for Humidification Systems
  • Type of Protection Against Electric Shock: Class II Equipment
  • Degree of Protection Against Electric Shock: Type BF Applied Part
  • Equipment Type: IPX1: Drip Proof Equipment
  • Mode of Operation: Continuous
  • Electromagnetic Compatibility: The device meets the requirements of EN 60601-1-2, 2nd edition.
  • HeaterPlate: 75° C (167° F)

System One Relative Humidity:

  • Setting 1 = 70%
  • Setting 2 = 80%
  • Setting 3 = 90%
  • Pressure Drop with Humidifier: (max.) 0.3cm H2O at 60 LPM flow
  • Humidity min Output: 10 mg H2O/L, measured at max flow, 35° C, 15% RH
  • Disposal: When necessary, dispose of the humidifier in accordance with local regulations.

Maximum Fill Level Tips

Do not fill the water tank above the maximum fill line. Damage to the humidifier or therapy device may occur. If the water tank is overfilled, water may leak out of the tank inlet (located on the back of the tank) when installing the tank lid.

Use only room temperature distilled water in the tank. Do not put any chemicals or additives into the water (like Essential Oils). Possible airway irritation or damage to the water tank may result.

Remove the tank, empty all water, and replace the empty tank before transporting the humidifier base. Do not attempt to fill the water tank while it is inside the humidifier.

To avoid spilling, do not disconnect the humidifier from the therapy device with water in the tank. Remove the water tank from the humidifier before disconnecting the therapy device.

Do not turn the humidifier on without the water tank installed. The Humidifier number setting must remain on 0 if there is no water in the water tank.

The humidifier door must be set in the open position before removing the water tank. Do not remove the water tank without making sure that the humidifier door locks into the open position.

Do not move the humidifier while the water tank has water in it.

PR System One Humidifier Modes

PR System One REMstar 60 machines version 1.22 or higher has two humidification modes:

  • Classic Humidification
  • System One Humidification

Version Note: To determine the version of software installed on a PR System One REMStar 60 machine, unplug the machine and plug it back into an outlet. The version is displayed on the screen when the unit is first plugged into an outlet. The humidification settings are displayed only when a PR System One Heated Humidifier is attached to the machine.

Classic Mode Humidification

The Classic mode of humidification allows the CPAP user to control the heat setting on the humidifier. The user will select "Classic" mode settings C1,C2, C3, C4 or C5. The "C" in front of the humidification setting indicates "Classic". C1 is the lowest level of humidification and C5 is the highest level of humidification.

System One Humidification Mode

The System One Humidification uses the technology of the system to set the level of humidification delivered. The machine makes the decision based on the humidity present in the room air. The CPAP user decides how much they want to receive. A setting of 1 delivers the lowest humidity level and a setting of 5 delivers the highest level. The humidification setting will show 1 - 5. The letter "C" will NOT precede the number.

Passover Humidification

Heat Off To turn the heated humidifier off, set the humidifier to zero "0". The air from the machine will pass over the water in the chamber acting as a passover Humidifier.

Setting the Humidification Mode and Level:

The humidifier menu will only show when the humidifier is attached to the machine.

  1. Using the wheel on the machine, select "Setup" menu. Scroll down the menu offerings to locate: "SYSTEM ONE humidification".
  2. Set to "On" to allow the technology of the machine to set the amount of humidification delivered to the system based on the setting of 1 -5. When in the SYSTEM ONE humidification mode there is no letter indicator next to the number.
  3. Set to "Off" to control the heat setting manually. The letter "C" is displayed in front of the humidification number to indicate "Classic". C1 is the lowest heat setting and C5 is the highest heat level.
  4. Set the humidification level by adjusting the number to the right of "Humidifier", the menu item below SYSTEM ONE humidification. 1 is the least and 5 is the most humidification.

Power Supply and DC Cable

The External 80 Watt Power Supply for PR System One REMstar 60 Series Machines included in this product is NOT compatible with other versions of PR System One machines.

The connection peg that plugs into a PR System One REMStar 60 Series machine is a specific size and will fit only these machines. The external power supply for these machines has different specifications than the External Power Supply for PR System One REMstar CPAP and BiPAP Machines used with other machines in the Philips Respironics lines.

The Power Cord that plugs the external power supply into the wall outlet is the same for all System One machines.

CPAP.com 100% Price Protection Guarantee

When you shop with us, we want you to be confident that you are receiving the best available price. If this items goes on sale or you spot an online or retail competitor with a lower price within seven days of your purchase, let us know, and we will credit you the difference.

"Super helpful, fast shipping, friendly assistance, great selection, I love this company."

- Verified Customer, 10/25/22

★★★★★

(9)  

Read Reviews

Need a personal touch?

Icon for Chat with CPAP

Chat with CPAP

Questions about a product or an existing order? Start a chat and let us help you out.

Start a chat

Icon for Call us

Call us

M-F 8am-8pm
Sat 8am-5pm (CST)

1.800.356.5221

Customer Reviews

See what other customers are saying.

Overall Rating
★★★★★
5.0 9 Reviews
5  Stars 
9
4  Stars 
0
3  Stars 
0
2  Stars 
0
1  Stars 
0
Sort By
★★★★★

Works well

Verified purchase | Jan. 21, 2024 | Rob S. | Recommended
This humidifier works very well on 60 Series machines.

Matches 60 Series machines

Requires daily maintenance.

Was this helpful?
(0)
(0)
★★★★★

Perfect Fit !!

Verified purchase | Apr. 16, 2021 | Verified CPAP.com Customer
I purchased a Heated Humidifier for my CPap machine and was worried that because my machine was a little older I wouldn't be able to get one , I found this one on CPAP.com and it was a perfect match , and the price was awesome
Was this helpful?
(0)
(0)
★★★★★

Doesn't work w/my machine but that's OK

Verified purchase | Oct. 06, 2020 | Verified CPAP.com Customer
I have a 50 series machine and this doesn't work. CPAP.com kindly offered me a refund. Had to buy a new machine even though all I needed was a humidifier. No regrets! My machine was old and worked but there have been advancements in CPAP technology (e.g. heated hose). So it was worth upgrading to a new machine. I've been using CPAP for almost 20 years now... my 4th machine.
Was this helpful?
(0)
(0)
★★★★★

Replacement humidifier

Verified purchase | Aug. 25, 2020 | Verified CPAP.com Customer
I purchased this humidifier to replace my 7 year old Philips humidifier that was acting up. This new humidifier works fine. I was glad to be able to get it because my System One CPAP machine is obsolete.
Was this helpful?
(0)
(0)
★★★★★

Seems To work just fine

Verified purchase | Feb. 25, 2016 | Verified CPAP.com Customer
It seems to work just fine, integrates well with the PR System One REMStar 60 Series Pro CPAP Machine with Bluetooth. I certainly appreciate the humidified air. Without the humidified air my airways are irritated in the morning.
Was this helpful?
(0)
(0)
★★★★★

Works well

Verified purchase | Feb. 03, 2016 | Verified CPAP.com Customer
This is the second one I have purchases. Works well. Easy to fill and clean.
Was this helpful?
(0)
(0)

Customers Also Viewed

Product image for Fisher & Paykel Humidification Starter Kit 900HC105
★★★★★
$44.99 $74.99

Fisher & Paykel Humidification Starter Kit 900HC105

Product image for Water Chamber for PR System One 60 Series CPAP Machines
★★★★★
$14.99

Water Chamber for PR System One 60 Series CPAP Machines

Product image for HC325 Replacement Water Chamber for HC100/150 Humidifiers
★★★★★
$14.25

HC325 Replacement Water Chamber for HC100/150 Humidifiers