AirSense 10 Supplies Bundle

ResMed
cpap.com is an authorized seller of all ResMed products

AirSense 10 Supplies Bundle

Regular price $82.49
Regular price Sale price $82.49
Sale Out of Stock
Shipping calculated at checkout.
Qty 1
1
2
3
4
  • Ships same day if ordered before 4 PM CST

  • Free shipping on orders over $99

  • checkmark icon

    100% price match guarantee

  • FSA/HSA eligible

  • The ResMed AirSense or AirCurve Series Basic Supplies Bundle gives you replacement parts and accessories for your AirSense 10 AutoSet Series CPAP Machine or AirCurve 10 Series Machine, including heated tubing, replacement filters, and a replacement water chamber for your ResMed CPAP machine . For all compatible supplies on the AirSense 10 Parts and AirCurve 10 Parts page. ResMed AirSense or AirCurve Series Basic Supplies Bundle Features and Benefits: Replacement Heated Tube Six Replacement Air Filters Replacement Humidifier Water Chamber Conveniently Provides Replacement CPAP Supplies Designed for AirSense and AirCurve Machines by ResMed Only Back-Up Supply Helps Prevent Potentially Dangerous Side Effects Caused by Missed Apnea Therapy Whether your current tubing becomes damaged or you run out of filters for your Resmed CPAP machine, having back–up filters, tubing, and water chamber ensures you can continue your sleep therapy. It is important not to miss CPAP therapy time since untreated sleep apnea can affect your cardiac health and lead to high blood pressure, stroke, or even dementia. Polyester Replacement Filters This is a 3rd party duplication of the standard filter that comes with your AirSense™ 10, AirStart™ 10, AirCurve™ 10, and S9 Series CPAP Machines. The AirSense™ 10 , AirStart™ 10, AirCurve™ 10 , and S9 line of CPAP machines does not use reusable foam and a disposable filter, like other machines. The standard air filter is a fibrous material that wards off large particulate matter like hair or dander. ClimateLine Air Heated Tube Maximum Recommended Pressure: 25 cm H2O Operating Altitude: Sea Level to 8500 feet Standard Water Chamber This is the Standard Water Chamber for AirSense™ 10, AirStart™ 10, and AirCurve™ Machines only and does not include any other items or accessories. This chamber is designed to open for cleaning. This chamber is NOT dishwasher safe. To view a dishwasher safe chamber, view the Dishwasher Safe Water Chamber for AirSense™ 10, AirStart™ 10, and AirCurve™ 10 Machines . General Tips Section Cleaning Tips For optimal performance, wash the heated tubing each week. Use warm water and mild shampoo to clean the tubing. Rinse well and allow it to dry away from sunlight. It is safe to completely submerge the hose in water as long as it is completely dry before connecting it to your Resmed machine or CPAP mask for use. Please Note: The tubing is NOT intended to be cleaned in a dishwasher or washing machine. Also, this hose is NOT compatible with the 15mm or 19mm CPAP Tube Brush. When cleaning the water chamber, please allow ten minutes after use for the chamber to cool before handling as it could be too warm to the touch. The machine will display a blue snowflake in the upper right of the screen while cooling is taking place. PLEASE NOTE: The Dishwasher Safe Water Chamber for the AirSense 10 CPAP machine features Injection Molded Plastic made of Polycarbonate in the bottom of the tank, and is able to be washed in the dishwasher. The Standard Water Chamber shown here uses a different type of Injection Molded Plastic and is not dishwasher safe. Placing in the dishwasher can cause loss or damage to CPAP equipment. Care and Cleaning: The chamber should be cleaned weekly by washing the tub in warm water and a mild detergent. Rinse well and allow to air dry. Do not allow the chamber to dry in direct sunlight or heat. Warranty Length: 90 Days Maximum Fill Level Tips Do not fill the water tank above the maximum fill line. Damage to the integrated humidifier or therapy device may occur. If the water tank is overfilled, water may leak out of the tank inlet (located on the side of the tank) when installing the tank lid. When disconnecting the hose from the tank outlet, be careful to ensure that the hose is not holding water. Water could travel through the hose and into the machine. Use only room temperature distilled water in the tank. Do not put any chemicals or additives into the water. Possible airway irritation or damage to the water tank may result. Remove the tank, empty all water, and replace the empty tank before transporting the humidifier base. Do not attempt to fill the water tank while it is inside the humidifier. To avoid spilling, do not disconnect the humidifier from the therapy device with water in the tank. Remove the water tank from the integrated humidifier before disconnecting the therapy device. Do not turn the humidifier on without the water tank installed. The Humidifier number setting must remain on 0 if there is no water in the water tank. The humidifier door must be set in the open position before removing the water tank. Do not remove the water tank without making sure that the humidifier door locks into the open position. Do not move the humidifier while the water tank has water in it. How to Determine if the Water Chamber is Dishwasher Safe? AirSense™ 10, AirStart™ 10, and AirCurve™ 10 machines denote the water chamber model with an "S" or "C" label. Look directly above the maximum fill line located on the side of the chamber to find the word HumidAir™ and the corresponding letter embossed into the tank. If the water chamber is dishwasher safe, the chamber will appear as HumidAir C, which represents a cleanable tank. If the water chamber is the standard model, the chamber will appear as HumidAir S, which represents a standard tank. Manufacturer Warranty This product comes with a 90 Day Manufacturer Warranty. CPAP.com will work with the manufacturer on your behalf if the product needs repairs. Please note: The manufacturer warranty is voided by water damage or misuse of the machine. airsense-maintenance-bundle
    SKUMP-MP-RMD-ASBAS
    Info Icon Product Info icons This product is coming soon. Mar. 13
    Product image for ResMed AirSense or AirCurve Series Basic Supplies Bundle

    AirSense 10 Basic Resupply Bundle

    Regular price $82.49
    Regular price Sale price $82.49
    Sale Out of Stock
    Added to Cart ()
    We Also Recommend

    Details

    More

    The ResMed AirSense or AirCurve Series Basic Supplies Bundle gives you replacement parts and accessories for your AirSense 10 AutoSet Series CPAP Machine or AirCurve 10 Series Machine, including heated tubing, replacement filters, and a replacement water chamber for your ResMed CPAP machine .

    For all compatible supplies on the AirSense 10 Parts and AirCurve 10 Parts page.

    ResMed AirSense or AirCurve Series Basic Supplies Bundle Features and Benefits:

    • Replacement Heated Tube
    • Six Replacement Air Filters
    • Replacement Humidifier Water Chamber
    • Conveniently Provides Replacement CPAP Supplies
    • Designed for AirSense and AirCurve Machines by ResMed Only

    Back-Up Supply Helps Prevent Potentially Dangerous Side Effects Caused by Missed Apnea Therapy

    Whether your current tubing becomes damaged or you run out of filters for your Resmed CPAP machine, having back–up filters, tubing, and water chamber ensures you can continue your sleep therapy. It is important not to miss CPAP therapy time since untreated sleep apnea can affect your cardiac health and lead to high blood pressure, stroke, or even dementia.

    Polyester Replacement Filters

    This is a 3rd party duplication of the standard filter that comes with your AirSense™ 10, AirStart™ 10, AirCurve™ 10, and S9 Series CPAP Machines.

    The AirSense™ 10 , AirStart™ 10, AirCurve™ 10 , and S9 line of CPAP machines does not use reusable foam and a disposable filter, like other machines. The standard air filter is a fibrous material that wards off large particulate matter like hair or dander.

    ClimateLine Air Heated Tube

    • Maximum Recommended Pressure: 25 cm H2O
    • Operating Altitude: Sea Level to 8500 feet

    Standard Water Chamber

    This is the Standard Water Chamber for AirSense™ 10, AirStart™ 10, and AirCurve™ Machines only and does not include any other items or accessories. This chamber is designed to open for cleaning. This chamber is NOT dishwasher safe. To view a dishwasher safe chamber, view the Dishwasher Safe Water Chamber for AirSense™ 10, AirStart™ 10, and AirCurve™ 10 Machines .

    General Tips Section

    Cleaning Tips

    For optimal performance, wash the heated tubing each week. Use warm water and mild shampoo to clean the tubing. Rinse well and allow it to dry away from sunlight. It is safe to completely submerge the hose in water as long as it is completely dry before connecting it to your Resmed machine or CPAP mask for use.

    Please Note: The tubing is NOT intended to be cleaned in a dishwasher or washing machine. Also, this hose is NOT compatible with the 15mm or 19mm CPAP Tube Brush.

    When cleaning the water chamber, please allow ten minutes after use for the chamber to cool before handling as it could be too warm to the touch. The machine will display a blue snowflake in the upper right of the screen while cooling is taking place.

    • PLEASE NOTE: The Dishwasher Safe Water Chamber for the AirSense 10 CPAP machine features Injection Molded Plastic made of Polycarbonate in the bottom of the tank, and is able to be washed in the dishwasher. The Standard Water Chamber shown here uses a different type of Injection Molded Plastic and is not dishwasher safe. Placing in the dishwasher can cause loss or damage to CPAP equipment.
    • Care and Cleaning: The chamber should be cleaned weekly by washing the tub in warm water and a mild detergent. Rinse well and allow to air dry. Do not allow the chamber to dry in direct sunlight or heat.
    • Warranty Length: 90 Days

    Maximum Fill Level Tips

    • Do not fill the water tank above the maximum fill line. Damage to the integrated humidifier or therapy device may occur. If the water tank is overfilled, water may leak out of the tank inlet (located on the side of the tank) when installing the tank lid.
    • When disconnecting the hose from the tank outlet, be careful to ensure that the hose is not holding water. Water could travel through the hose and into the machine.
    • Use only room temperature distilled water in the tank. Do not put any chemicals or additives into the water. Possible airway irritation or damage to the water tank may result.
    • Remove the tank, empty all water, and replace the empty tank before transporting the humidifier base.
    • Do not attempt to fill the water tank while it is inside the humidifier.
    • To avoid spilling, do not disconnect the humidifier from the therapy device with water in the tank. Remove the water tank from the integrated humidifier before disconnecting the therapy device.
    • Do not turn the humidifier on without the water tank installed. The Humidifier number setting must remain on 0 if there is no water in the water tank.
    • The humidifier door must be set in the open position before removing the water tank. Do not remove the water tank without making sure that the humidifier door locks into the open position.
    • Do not move the humidifier while the water tank has water in it.

    How to Determine if the Water Chamber is Dishwasher Safe?

    AirSense™ 10, AirStart™ 10, and AirCurve™ 10 machines denote the water chamber model with an "S" or "C" label. Look directly above the maximum fill line located on the side of the chamber to find the word HumidAir™ and the corresponding letter embossed into the tank.

    • If the water chamber is dishwasher safe, the chamber will appear as HumidAir C, which represents a cleanable tank.
    • If the water chamber is the standard model, the chamber will appear as HumidAir S, which represents a standard tank.

    Manufacturer Warranty

    This product comes with a 90 Day Manufacturer Warranty. CPAP.com will work with the manufacturer on your behalf if the product needs repairs.

    Please note: The manufacturer warranty is voided by water damage or misuse of the machine.

    airsense-maintenance-bundle

    Specs

    More

    Fast, free shipping on orders over $99

    Get the best price with our 100% Price Protection Guarantee

    Discounted replacements with Subscribe & Save

    Try any CPAP mask for 30 days, risk-free 

    Shop Your Recently Viewed