- Battery Amp Hours: 8 Ah
- Charging Time: 4 Hours
- Shelf Life of Charge: Up To 3 Months
- Recharging Requirement: Battery MUST Be Recharged Every 3 Months To Maintain Functionality
- Battery Life: 500 Charging Cycles
- Input Voltage: 100-240V
User Manual:
The user manual included with this external lithium-ion battery pack can be viewed and downloaded here: Power Station User Guide.
ResMed FAA Compliance Letter: To view the ResMed FAA Compliance Listing click: HERE.
Please note: The RPS II has a voltage output selector on the back panel of the unit which can be used to change from 24v to 26v power. All S9 or AirSense™/AirCurve™ 10 CPAP and VPAP devices require 24v with and without the use of a humidifier.
To Power an S9 or AirSense™/AirCurve™ 10 Machine on the ResMed Power Station:
- Select "24v" output on the back panel of the ResMed Power Station II
- Connect the S9 Series DC Cable for ResMed Power Station (RPS) II or AirSense™/AirCurve™ 10 Series DC Cable for ResMed Power Station (RPS) II to the ResMed Power Station
- Remove the cap from the other end of the S9 or the AirSense™/AirCurve™ 10 Series DC Cable for ResMed Power Station
- Connect the uncapped end of the S9 or the AirSense™/AirCurve™ 10 Series DC Cable for ResMed Power Station to the S9 or AirSense™/AirCurve™ 10 machine in the port, where the power cord is normally connected to the CPAP device.
- Turn on the ResMed Power Station
- Turn the S9 or AirSense™/AirCurve™ 10 machine on as normal
The ResMed Power Supply Unit (PSU) Adapter for both the S9 and the AirSense™ 10/AirCurve™ 10 machines are NOT used to operate the RPS II. During use, the S9 or AirSense™/AirCurve™ 10 Series DC Cable for ResMed Power Station (RPS) II connects directly between the RPS II and the S9 or AirSense™/AirCurve™ 10 machines.
The S9 Series DC Cable for ResMed Power Station (RPS) II and the AirSense™ 10 and AirCurve™ 10 Series DC Cable for ResMed Power Station (RPS) II are for use ONLY with the ResMed Power Station II and are not compatible with other DC sources.
To Charge the ResMed Power Station:
- Connect the Power Supply Unit (PSU) Adapter for ResMed Power Station (RPS) II to the ResMed Power Station
- Connect the External Power 90 Watt Supply for ResMed S9 Series Machines or the External Power 90 Watt Supply for ResMed AirSense™ 10/AirCurve™ 10 Series Machines to the PSU Adapter
- Plug the S9 or the AirSense™ 10/AirCurve™ 10 Power Supply into an AC wall outlet
- The "charging" light will show until the battery is fully charged
- If unused, the battery MUST be recharged every three (3) months
Depending on the machine being used, the Power Supply Unit (PSU) Adapter for S9 Machines for ResMed Power Station (RPS) II or the Power Supply Unit (PSU) Adapter for AirSense™ 10 and AirCurve™ 10 Machines for ResMed Power Station (RPS) II are required to charge the RPS II. The PSU connects the RPS II to both the S9 External Power Supply and the AirSense™ 10/AirCurve™ 10 Power Supply.
The S9 Power Supply Unit and the AirSense™ 10/AirCurve™ 10 Power Supply Unit that come standard with all S9 or AirSense™ 10/AirCurve™ 10 machines are used to charge the ResMed Power Station II. The S9 and AirSense™ 10/AirCurve™ 10 power supply are not included with the battery.
The manufacturer warranty for the ResMed Power Station II is 6 months.
Recharging Requirement: When storing the ResMed Power Station, if it is unused for a period of THREE (3) months the battery MUST be recharged to maintain the functionality of the battery. Per the manufacturer, if the battery is not recharged it will eventually discharge completely and no longer be able to be recharged and there will not a way in which to recover the functionality of the battery.
Please contact CPAP.com with questions. Call toll-free: 1-800-356-5221 or email to cpap@cpap.com.