Sign up for our newsletter to receive CPAP tips and special offers!

    IntelliPAP 2 AutoAdjust Auto CPAP Machine

    Profile View of the IntelliPAP 2 AutoAdjust Auto CPAP Machine with Billiard Ball (Billiard Ball Not Included)Front View of the IntelliPAP 2 AutoAdjust Auto CPAP Machine with Billiard Ball (Billiard Ball Not Included)IntelliPAP 2 AutoAdjust Auto CPAP Machine - Profile View with Billiard Ball (Billiard Ball and Humidifier Not Included)Front View of IntelliPAP 2 AutoAdjust Auto CPAP Machine and Heated Humidifier (Humidifier Not Included)Side View of IntelliPAP 2 AutoAdjust Auto CPAP Machine and Heated Humidifier (Humidifier Not Included)Back View of IntelliPAP 2 AutoAdjust Auto CPAP Machine and Heated Humidifier (Humidifier Not Included)Back View of the IntelliPAP 2 Heated Humidifier Water Chamber and Humidifier Cradle (Humidifier and Water Chamber Not Included)Front View of the Water Chamber for IntelliPAP 2 Heated Humidifier (Water Chamber Not Included)Side View of the IntelliPAP 2 Heated Humidifier Water Chamber and Humidifier Cradle (Not Included)Water Chamber for IntelliPAP 2 Heated Humidifier - Vertical View (Water Chamber Not Included)IntelliPAP 2 AutoAdjust Auto CPAP Machine with Clock DisplayFront View of the IntelliPAP 2 AutoAdjust Auto CPAP MachineProfile View of the IntelliPAP 2 AutoAdjust Auto CPAP MachineBack View of the IntelliPAP 2 AutoAdjust Auto CPAP MachineIntelliPAP 2 Carry BagSide View of the IntelliPAP 2 Carry BagIntelliPAP 2 65 Watt Power Supply and Cord
    Product Images
    • Profile View of the IntelliPAP 2 AutoAdjust Auto CPAP Machine with Billiard Ball (Billiard Ball Not Included)
    • Front View of the IntelliPAP 2 AutoAdjust Auto CPAP Machine with Billiard Ball (Billiard Ball Not Included)
    • IntelliPAP 2 AutoAdjust Auto CPAP Machine - Profile View with Billiard Ball (Billiard Ball and Humidifier Not Included)
    • Front View of IntelliPAP 2 AutoAdjust Auto CPAP Machine and Heated Humidifier (Humidifier Not Included)
    • Side View of IntelliPAP 2 AutoAdjust Auto CPAP Machine and Heated Humidifier (Humidifier Not Included)
    • Back View of IntelliPAP 2 AutoAdjust Auto CPAP Machine and Heated Humidifier (Humidifier Not Included)
    • Back View of the IntelliPAP 2 Heated Humidifier Water Chamber and Humidifier Cradle (Humidifier and Water Chamber Not Included)
    • Front View of the Water Chamber for IntelliPAP 2 Heated Humidifier (Water Chamber Not Included)
    • Side View of the IntelliPAP 2 Heated Humidifier Water Chamber and Humidifier Cradle (Not Included)
    • Water Chamber for IntelliPAP 2 Heated Humidifier - Vertical View (Water Chamber Not Included)
    • IntelliPAP 2 AutoAdjust Auto CPAP Machine with Clock Display
    • Front View of the IntelliPAP 2 AutoAdjust Auto CPAP Machine
    • Profile View of the IntelliPAP 2 AutoAdjust Auto CPAP Machine
    • Back View of the IntelliPAP 2 AutoAdjust Auto CPAP Machine
    • IntelliPAP 2 Carry Bag
    • Side View of the IntelliPAP 2 Carry Bag
    • IntelliPAP 2 65 Watt Power Supply and Cord
    See More Images

    IntelliPAP 2 AutoAdjust Auto CPAP Machine

    DeVilbiss' IntelliPAP 2 AutoAdjust Auto CPAP Machine features comfort technology and OPTIONAL humidification while auto-adjusting pressure to meet various breathing events. The machine and OPTIONAL IntelliPAP 2 Standard Heated Humidifier offer a smaller footprint when stacked together.

    Manufactured by DeVilbiss.

    DeVilbiss' IntelliPAP 2 AutoAdjust Auto CPAP Machine features comfort technology and OPTIONAL humidification while auto-adjusting pressure to meet various breathing events. The machine and OPTIONAL IntelliPAP 2 Standard Heated Humidifier offer a smaller footprint when stacked together.

    Product Features

    The IntelliPAP 2 AutoAdjust Auto CPAP Machine from DeVilbiss is a travel-sized CPAP machine designed to automatically adjust pressure during the night. The machine uses multiple techniques to track therapy effectiveness including a SD card (included), bluetooth technology, and SmartCode.

    Features

    • "PureView" AutoAdjust Algorithm
    • Large LCD Screen Display
    • SmartCode Adherence Score
    • OPTIONAL Heated Humidifier
    • Bluetooth Capable Technology
    • SmartFlex & Adjustable Rounding
    • Ramp Comfort Feature
    • Auto Start / Auto Stop

    "PureView" AutoAdjust Algorithm

    The "PureView" AutoAdjust Algorithm is a unique feature used on the AutoAdjust CPAP machine to detect advanced apnea events such as: periodic breathing and flow limitation. This algorithm uses a logic that understands complex issues, leading to automatic changes in pressure in response to OSA and CSA events. This is an auto-adjusting machine that will operate between a low and high pressure range, remaining at the lower pressure until an event is detected requiring a higher pressure.

    Large LCD Screen Display

    The sharp LCD screen increases the visibility of displayed information and pairs with a knob that is turned and pressed for easy navigation of menus and settings. The display can also show regular reminders to change filters and clean equipment, if desired. When in standby, the machine will display a clock and also has an alarm clock function.

    On-Screen Data Includes:

    • AHI
    • Leak Rate
    • Usage Information

    SmartCode Adherence Score

    SmartCode messages begin to display on the screen after the first night of therapy. Each code is a uniquely encrypted code holding personal sleep data results. SmartCode is intended to help IntelliPAP 2 users become compliant. Review the SmartCode Adherence Score with a physician.

    SmartCode Adherence is determined after the machine is used for 30 consecutive days. Data can be generated to depict results from the following:

    • 1 Day
    • 7 Days
    • 30 Days
    • 90 Days
    • A Cumulative Report

    OPTIONAL Heated Humidifier

    Devilbiss offers two integrated humidifiers for use with the IntelliPAP 2 machines. Warm, moist air travels through the hose to the mask to provide comfort to the user. The humidifiers attach to the base of the machine, so only the height is increased with the two are used together. The IntelliPAP 2 Auto machine can be paired with both versions of the IntelliPAP 2 Heated Humidifier:

    • Standard Heated Humidifier: The standard humidifier can be set to a level ranging from 0-5 and will heat to provide that level of moisture all night long during inhalation and exhalation. Level 0 provides no heat, while level 5 provides the most heat.
    • Pulse Dose Humidifier: The Pulse Dose feature provides moisture during inhalation only. During exhalation, the humidifier is bypassed, helping to clear moisture out of the hose, retain water in the chamber for a longer period of time, and reduce power draw from the machine and humidifier. The humidifier can be set from 0-5 with 0 being no heat and 5 being the highest heat setting.

    Bluetooth Capable Technology

    Enable the Bluetooth feature to begin pairing the IntelliPAP 2 to the SmartLink app designed by DeVilbiss. The SmartLink Data Management System is designed for use on Apple and Android devices. To begin using the app, visit the iTunes App Store or the Google Play Store depending on the device. Search "DeVilbiss SmartLink" to locate the SmartLink app. Once the app has been downloaded and the Bluetooth option is turned ON, data will begin streaming from the machine to the handheld device.

    The SmartLink app is compatible with the following devices:

    • iPhone, iPad, or iPod touch running Apple iOS 8 or newer
    • Android smartphones and tablets running 4.0.3 or newer

    SmartFlex & Adjustable Rounding

    SmartFlex is designed to decrease pressure during exhalation 1, 2, or 3 cm for a more comfortable breathing pattern during therapy.

    Adjustable rounding allows the user to customize the transition between exhalation to inhalation and inhalation to exhalation. The machine settings range from 0 to 5. Level 0 represents a direct jump in pressure, while level 5 represents the softest transition.

    Ramp Comfort Feature

    The IntelliPAP 2 AutoAdjust offers Ramp as a comfort feature. Ramp is designed to gradually increase therapy to the lower pressure of the auto range over a period of time. Between 0 to 45 minutes, the machine will slowly raise the pressure to help the user become acclimated to their therapy so they may fall to sleep with ease. The ramp button is on top of the machine and to the right of the humidifier symbol. Use the button to start or stop ramp. Please Note: If the machine’s lower pressure of the auto range is 3, ramp will not be available.

    Auto Start / Auto Stop

    The Auto Start / Auto Stop feature allows the user to begin and finish CPAP therapy without manually pressing a button. When enabled, place the mask against the face and begin breathing into the mask to start sleep therapy. Likewise, remove the mask when waking to stop sleep therapy. If the Auto Start / Auto Stop feature is not desired, the machine is equipped with button to manually control the device.


    Return On Warranty Issues Only

    Specifications

    This Product Includes...

    • IntelliPAP 2 AutoAdjust Auto CPAP Machine
    • Carrying Case
    • 6 Foot Long 15mm Slim Tubing
    • Filter Cover
    • Reusable Filter
    • Disposable Filter
    • SD Card
    • Power Supply
    • Power Cord
    • Manual

    Product Specifications

  • Dimensions - Machine Alone: 6.1 in L x 5.9 in W x 3.7 in H (15.49 cm L x 14.99 cm W x 9.40 cm H)

  • Dimensions - Machine and OPTIONAL Humidifier (Excluding Air Outlet Port): 11.7 in L x 7.6 in W x 3.3 in H (29.72 cm L x 19.30 cm W x 8.38 cm H)

  • Weight - Machine Alone: 1.93 lbs (0.9 kg)

  • Weight - Machine and Humidifier: 3.8 lbs (1.75 kg)

  • Power Consumption - 65W Power Supply: 100 - 240V, 50/60 Hz

  • DC Electrical Requirements: 11 - 17 VDC, 5.2 Amps

  • Operating Pressure Range: 3 - 20 cm H2O (0.5cm increments)

  • Ramp Time : 0 - 45 minutes (5 minute increments)

  • Ramp Pressure: 4 - 20 cm H2O

  • Operating Temperature Range: 41 degree F to 104 degree F (5 degree C to 40 degree C)

  • Operating Humidity Range: 15% to 93% RH non-condensing

  • Operating Atmospheric Conditions: 1060 hPa - 700 hPa (1,400 ft below sea level to 9,800 feet)

  • Storage and Transportation Temperature Range: -13 degree F to 158 degree F (-25 degree C to 70 degree C)

  • Storage and Transportation Humidity Range: 15% to 93% RH non-condensing

  • Sound Pressure Level:<26.6 dBA

  • Sound Power Level:<34.6 dBA

  • Machine Warranty: 3 years

  • Dimensions - Carry Bag: 11 in L x 5.5 in W x 8.5 in H (27.94 cm L x 13.97 cm W x 21.59 cm H)

  • CPAP.com always offers these services:

    • 8 am to 8 pm CST Toll Free Phone and Email Support
    • 24 hour access to our CPAPtalk.com Support Forum
    • Learning Center for information on sleep apnea and cpap equipment
    • Consumer Purchasing Trends Reports
    • Warranty Services for all items purchased through CPAP.com
    • Insurance Compliant Invoices
    • Free Prescription Request System

    Important Tips

    Tips to Position the IntelliPAP 2 onto the OPTIONAL Humidifier

    When placing the machine on top of the humidifier cradle, ensure the display is facing the same direction as the pale blue tab on the water chamber. Then, when removing the machine from the cradle, lightly push inward on the rectangular button near the rear corner of the cradle. When properly positioned, the units are easily attached and dismantled.

    Compatible Replacement Parts

    Please Note: Some of the parts used on the original IntelliPAP are also compatible with IntelliPAP 2 machines. Other parts are strictly designed for the IntelliPAP 2.

    • These disposable filters and reusable filters are compatible with both the IntelliPAP and the IntelliPAP 2. However, the IntelliPAP 2 has a filter cover which was not used on the original machine.
    • The IntelliPAP 2 comes with a 6 Foot Long 15mm slim hose. If the user prefers to use a longer hose or a hose with a 22mm diameter, the settings may be changed on the machine to accommodate the hose, with the exception of a heated hose.
    • The IntelliPAP 2 has a power supply attached to the power cord. This design is different from the original power cord used with the IntelliPAP machines.

    Air Supply Port Cover

    The functionality of the device is dependent upon the placement of the air supply port cover. There are two ways to utilize the cover:

    • When the IntelliPAP 2 machine and humidifier are connected, the air supply port cover folds into the circular crevice located on the back of the IntelliPAP 2 machine.
    • If using the IntelliPAP 2 machine without the humidifier, reposition the air supply port cover so it coats the circular opening found on the bottom of the IntelliPAP 2 machine. Please Note: The cover must be put back into the opening found on the back of the machine when preparing to reconnect the machine and humidifier. If the cover is still protecting the hole on the bottom of the machine, the devices will not fasten.

    Water Chamber Cleaning Tips

    The water chamber for the IntelliPAP 2 Heated Humidifier needs to be cleaned daily. Please Note: The water chamber may be placed in the dishwasher for an occasional cleaning. When placed in the dishwasher, the chamber must sit on the top rack. For all other daily needs, hand wash the chamber with warm water and mild soap.

    Before cleaning the chamber, the user will need to remove the tank from the humidifier cradle. Follow these steps to withdraw the chamber:

    • Gently press on the chamber release latch which is located at the front of the chamber.
    • Slide the chamber out of the cradle.
    • Locate and push forward on the chamber disassembly lever which is directly behind the chamber release latch.
    • The chamber will open into two halves.

    Cleaning Tips for the Humidifier Cradle

    The cradle which holds the water chamber should be cleaned weekly. Please Note: The cradle should not be submerged in water. Instead, use a moist cloth to wipe the exterior of the unit. Follow these steps when preparing the clean the cradle:

    • Remove the power source to allow the heater plate to cool. The cooling process may take up to 10 minutes.
    • Once cooled, withdraw the water chamber from the inside of the cradle.
    • Use the flow generator release button to separate the IntelliPAP 2 machine from the cradle base.
    • Use a moist towel to cleanse the cradle.

    Instructions for Filling the Water Chamber

    When refilling the water chamber, use distilled water to help prevent mineral build-up. The IntelliPAP 2 water chamber has water level indicators located on the sides and top of the chamber. Do not surpass the specified markings when refilling the chamber, as it may cause water damage.

    Sealing Gasket Maintenance

    Before each use, examine the sealing gasket surrounding the circumference of the chamber. Ensure the gasket has been put back into place after each cleaning.



    Power Options

    Universal Power

    The DeVilbiss IntelliPAP 2 system operates automatically between 110v and 240v AC. When traveling either inside or outside the USA, there are no switches to switch or fuses to change. The machine will automatically sense what voltage is needed and set itself to run on that power.

    The user will need to adapt the plug that goes into the wall to fit the style of outlet socket that is being used. This is simply done with a Power Adapter Plug Kit. This is the same type of plug adapter that would be used with a hair dryer or an electric shaver. World Traveler Power Adapter Plugs.

    DC Power Cord for IntelliPAP 2 CPAP Machines

    The DC Power Cord for IntelliPAP 2 CPAP Machines plugs into the back of the IntelliPAP 2 units, allowing the user to connect the CPAP to an external DC battery source. The IntelliPAP can be powered by plugging the 12V DC Power Cord into a cigarette lighter plug. This is ideal for traveling by car, boat, or recreational vehicle that is equipped with a cigarette lighter plug.

    Important Note: If using the OPTIONAL heated humidifier, the IntelliPAP 2 machines cannot be operated from DC power. A modified sine wave inverter of at least 120V AC is necessary to power both the machine and humidifier from a DC power source.

    These are the compatible inverters:

    Battery Backup Option

    Because the IntelliPAP 2 machines use a separate connection for AC and DC power, they can be set up in a battery backup configuration. The AC power cord is plugged AC power source such as a wall outlet, and the OPTIONALDC Power Cord for IntelliPAP 2 CPAP Machines is plugged into a DC power source such as a battery. The IntelliPAP will use the AC power source when available, otherwise will convert to the DC power source, without any interruption in therapy. If the AC power source becomes available again, the machine will revert back. Please note that if using the heated humidifier, it will not function from DC power.

    Freedom Travel Battery Pack for CPAP Machines

    Weighing in at only 1.7 pounds the Freedom Battery is a terrific option for travel. Pair the DC input cord included with the battery and the DC Power Cord for IntelliPAP 2 CPAP Machines to connect to the Freedom battery. This lithium ion battery meets UN Manual Test and Criteria requirements for travel.

    Replacement Parts

     Get Help